3. WARNING: SUBSTITUTION OF COMPONENTS MAY IMPAIR INTRINSIC SAFETY.
4. NO REVISION TO DRAWING WITHOUT PRIOR CSA-INTERNATIONAL APPROVAL.
5. ASSOCIATED APPARATUS MANUFACTURER'S INSTALLATION DRAWING MUST BE FOLLOWED WHEN INSTALLING THIS EQUIPMENT.
6. INSTALLATION IN CANADA SHOULD BE IN ACCORDANCE WITH THE CANADIAN ELECTRICAL CODE, CSA C22.1, PART 1, APPENDIX F.
7. INSTALLATION SHALL BE IN ACCORDANCE WITH THE
NATIONAL ELECTRICAL CODE (ANSI / NFPA 70) SECTIONS 504 AND 505 AND THE
ANSI / ISA RP12.6 INSTALLATION OF INTRINSICALLY SAFE
SYSTEMS FOR HAZARDOUS (CLASSIFIED) LOCATIONS.
8. THE MAXIMUM NON-HAZARDOUS LOCATION VOLTAGE IS 250V AC/DC.
1. REFER TO TRANSMITTER'S INSTALLATION MANUAL FOR TRANSDUCER LOCATION AND MOUNTING INSTRUCTIONS.
2. WARNING - TO PREVENT IGNITION OF FLAMMABLE ATMOSPHERES, DISCONNECT POWER BEFORE SERVICING.
990' MAX.
(302 METERS)
(RG-59/U COAX, BELDEN 9463, OR
BELDEN 9463DB OR EQUAL ONLY)
NON-HAZARDOUS LOCATIONHAZARDOUS (CLASSIFIED) LOCATION
DYNASONICS I.S. BARRIER
MODEL D070-1010-002
3' MIN.
(0.93 METERS)
(2 PLACES)
SENSING SURFACE: COUPLE TO
PIPE WITH RTV OR SILICONE
GREASE SUPPLIED, PER INSTALLATION
MANUAL TFXD O&M.
RED/BLUE
BLACK/CLEAR
RED/BLUE
BLACK/CLEAR
TRANSMITTER PER
CONNECT TO
INSTALLATION
MANUAL
I.S. MODULE
PART NO. D070-1010-001
CLASS I, DIVISION 1 GROUPS C AND D
MAXIMUM AMBIENT TEMPERATURE: -40° TO +85°C
DYNASONICS DTT SERIES
TRANSDUCERS
MODEL NO: DTTN-xxx-N000-F
I.S. WIRING
MAXIMUM AMBIENT TEMPERATURE: -40°C TO 50°C
10' MAX
3.60
(MTG. HOLES)
6.26
(MTG. HOLES)
B
1
C
1
SAFE HAZ
HAZ
SAFE
MODEL: 070-1010-002 I.S. Barrier-Ultrasonics
D003-0905-117
FIGURE A6.1  CONTROL DRAWING I.S. BARRIER DTT TRANSDUCERS